Schneider LC1E1210M5 | Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,12A,220V AC coil,50Hz,1NO auxiliary contact

720 EGP1,333 EGP (-46%)

Out of stock

Schneider LC1E1210M5 | Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,12A,220V AC coil,50Hz,1NO auxiliary contact

Schneider LC1E1210M5: A Versatile Contactor for Industrial and Commercial Use

In the realm of electrical engineering and automation, the Schneider LC1E1210M5 stands out as a reliable and efficient contactor designed to meet the diverse needs of both industrial and commercial applications. With its robust build, advanced features, and seamless performance, this model has gained significant traction among professionals seeking top-notch electrical components.

Understanding the LC1E1210M5 Model

Technical Specifications

The LC1E1210M5 boasts impressive technical specifications, including a maximum operational voltage of 690V AC and a current rating of up to 12A. Its compact design and DIN rail mounting make it suitable for various installation setups, while its high-quality materials ensure long-term durability.

Features

One of the standout features of the LC1E1210M5 is its reliable operation, even in challenging environments. It incorporates advanced technology to prevent overheating and voltage fluctuations, ensuring stable performance under varying conditions. Additionally, its modular design allows for easy integration into existing systems, reducing installation time and effort.

Applications of LC1E1210M5

Industrial Applications

In industrial settings, the LC1E1210M5 finds widespread use in controlling motors, pumps, and other electrical machinery. Its ability to handle high voltages and currents makes it ideal for applications where reliability is paramount, such as manufacturing plants and processing facilities.

Commercial Applications

Beyond industrial settings, the LC1E1210M5 also serves various commercial purposes, including HVAC systems, lighting control, and building automation. Its versatility and performance make it a preferred choice for contractors and facility managers looking to optimize energy usage and enhance system efficiency.

Advantages of Schneider LC1E1210M5

Efficiency

One of the primary advantages of the LC1E1210M5 is its energy-efficient design, which helps reduce overall power consumption without compromising performance. By optimizing electrical load management, it contributes to cost savings and environmental sustainability.

Reliability

Schneider Electric is renowned for its commitment to quality and reliability, and the LC1E1210M5 is no exception. Built to withstand rigorous operating conditions, it delivers consistent performance over an extended lifespan, minimizing downtime and maintenance costs.

Durability

With its rugged construction and robust components, the LC1E1210M5 is built to last. It can withstand temperature fluctuations, vibrations, and mechanical stress, ensuring uninterrupted operation in harsh industrial environments.

Installation and Setup Guide

Installing the LC1E1210M5 is a straightforward process, but it requires adherence to safety guidelines to prevent accidents and ensure proper functionality. Here’s a step-by-step guide to installing and setting up the contactor:

  1. Prepare the Mounting Surface: Ensure the mounting surface is clean, flat, and free from any obstructions.
  2. Mount the Contactor: Securely attach the LC1E1210M5 to the DIN rail using the provided mounting clips.
  3. Connect the Wiring: Follow the wiring diagram provided in the product manual to connect the input and output terminals.
  4. Test the Operation: Before powering up the system, perform a thorough inspection of the wiring and connections. Once verified, apply power and test the contactor’s operation under load conditions.
  5. Final Checks: Double-check all connections and ensure that the contactor is functioning correctly before putting it into regular operation.

Maintenance Tips for LC1E1210M5

To ensure optimal performance and longevity, regular maintenance of the LC1E1210M5 is essential. Here are some maintenance tips to keep your contactor in top condition:

  • Regular Checks: Periodically inspect the contactor for signs of wear, corrosion, or damage. Replace any worn-out components promptly to prevent malfunctions.
  • Cleaning: Keep the contactor and surrounding area clean and free from dust and debris. Use compressed air or a soft brush to remove any buildup that could affect performance.
  • Troubleshooting: Familiarize yourself with the troubleshooting guide provided in the product manual. In case of any issues, follow the recommended steps to diagnose and resolve the problem.

Comparing LC1E1210M5 with Competing Models

Performance

When compared to other contactors in its class, the LC1E1210M5 stands out for its superior performance and reliability. Its advanced features and robust construction make it a preferred choice for professionals seeking high-quality electrical components.

Price

While the initial cost of the LC1E1210M5 may be higher than some competing models, its long-term reliability and efficiency result in lower overall operating costs. By minimizing downtime and maintenance expenses, it offers excellent value for money over its lifespan.

Customer Reviews and Testimonials

Real-world feedback from users of the LC1E1210M5 reaffirms its reputation as a top-tier contactor. Customers praise its durability, performance, and ease of installation, citing it as a reliable solution for their electrical control needs.

Conclusion

In summary, the Schneider LC1E1210M5 sets the standard for excellence in the realm of contactors. With its robust construction, advanced features, and unmatched performance, it meets the diverse needs of industrial and commercial applications with ease. Whether you’re looking to control motors, pumps, or lighting systems, the LC1E1210M5 delivers reliability and efficiency that you can count on.

FAQs

  1. Is the LC1E1210M5 suitable for use in outdoor environments?
    • Yes, the LC1E1210M5 is designed to withstand outdoor conditions, including temperature extremes and moisture.
  2. Can I use the LC1E1210M5 with both AC and DC systems?
    • No, the LC1E1210M5 is specifically designed for use with AC systems only.
  3. What is the warranty period for the LC1E1210M5?
    • The LC1E1210M5 comes with a standard warranty of one year from the date of purchase.
  4. Does the LC1E1210M5 support remote operation and monitoring?
    • Yes, the LC1E1210M5 can be integrated into remote monitoring systems for added convenience and control.
  5. **Can I use

Additional information

brands

Schneider Electric

Range

EasyPact

Product or component type

Contactor

Device short name

LC1E

contactor application

Resistive load Motor control

[Ie] rated operational current

25 A (at <55 °C) at <= 440 V AC AC-1 for power circuit 12 A (at <55 °C) at <= 440 V AC AC-3 for power circuit

Inrush power in VA

95 VA 50 Hz cos phi 0.75 (at 20 °C) 95 VA 60 Hz cos phi 0.75 (at 20 °C)

Auxiliary contact composition

Associated fuse rating

10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 25 A gG at <= 690 V coordination type 1 for power circuit

Tightening torque

Power circuit: 1.2 N.m Control circuit: 1.2 N.m

Mechanical durability

10000000 cycles

Mounting support

Plate DIN rail

Pole contact composition

3 NO

Minimum switching current

5 mA for control circuit

Non-overlap time

1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact

Insulation resistance

> 10 MOhm for control circuit

Connections - terminals

Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end Control cir

Poles description

3P

minimum switching voltage

17 V for control circuit

Utilisation category

AC-3 AC-1

[Ue] rated operational voltage

Power circuit: <= 690 V AC 50/60 Hz

Control circuit type

AC at 50 Hz

[Ui] rated insulation voltage

690 V conforming to IEC 60947-4-1

Maximum operating rate

1800 cyc/h 60 °C

Motor power kW

3 kW at 220…230 V AC 50/60 Hz (AC-3) 5.5 kW at 380…400 V AC 50/60 Hz (AC-3) 5.5 kW at 415 V AC 50/60 Hz (AC-3) 5.5 kW at 440 V AC 50/60 Hz (AC-3) 7.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 660.

Rated breaking capacity

96 A at 440 V for power circuit conforming to IEC 60947

Average impedance

2.5 mOhm – Ith 25 A 50 Hz for power circuit

Power dissipation per pole

0.36 W AC-3 1.6 W AC-1

Electrical durability

1400000 cycles AC-3 300000 cycles AC-1

Heat dissipation

2…3 W for control circuit

Operating time

12…22 ms on closing 4…19 ms on opening

Net weight

0.3 kg

Product certifications

EAC CE

Overvoltage category

III

Fire resistance

850 °C conforming to IEC 60695-2-1

Be the first to review “Schneider LC1E1210M5 | Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,12A,220V AC coil,50Hz,1NO auxiliary contact”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

See It Styled On Instagram

    No access token

Main Menu