Schneider LC1E1201E7 | Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,12A,48V AC coil,50/60Hz,1NC auxiliary contact
Roll over image to zoom in
720 EGP1,333 EGP (-46%)
Schneider LC1E1201E7 | Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,12A,48V AC coil,50/60Hz,1NC auxiliary contact
Schneider LC1E1201E7: Understanding the Description
When it comes to electrical components, precision and reliability are paramount. Schneider LC1E1201E7 is a contactor that exemplifies these qualities. In this article, we’ll delve into the description of Schneider LC1E1201E7, exploring its technical specifications, features, applications, and more.
Technical Specifications
Schneider LC1E1201E7 boasts impressive technical specifications, making it suitable for a variety of electrical applications. It offers voltage and current ratings that ensure efficient performance in diverse settings. With multiple coil voltage options and a configurable contact arrangement, it provides flexibility to meet specific project requirements.
Features and Benefits
The Schneider LC1E1201E7 is equipped with a range of features that set it apart in the market. From its robust construction to advanced functionality, each aspect contributes to its reliability and longevity. Users can benefit from its superior performance, enhanced safety features, and ease of installation.
Applications
This contactor finds its place in various sectors, including industrial, commercial, and residential. Its versatility makes it suitable for controlling electrical circuits in machinery, HVAC systems, lighting, and more. Whether it’s powering heavy machinery or managing building automation systems, the Schneider LC1E1201E7 proves to be a dependable choice.
Installation and Operation
Installing and operating the Schneider LC1E1201E7 is straightforward, thanks to its user-friendly design and clear instructions. Proper installation ensures optimal performance and longevity. Understanding its operating principles enables users to utilize its capabilities effectively.
Comparison with Alternatives
In comparison to other contactors on the market, the Schneider LC1E1201E7 offers distinct advantages. Its superior build quality, advanced features, and competitive pricing make it a preferred choice among professionals. When weighed against alternatives, it emerges as a reliable and cost-effective solution.
Maintenance and Troubleshooting
Regular maintenance is essential to prolong the lifespan of the Schneider LC1E1201E7. Fortunately, it requires minimal upkeep, thanks to its durable construction and efficient design. In the event of issues, troubleshooting steps are available to diagnose and resolve problems promptly.
Customer Reviews
Feedback from customers who have used the Schneider LC1E1201E7 is overwhelmingly positive. Users commend its performance, reliability, and value for money. Real-world experiences highlight its effectiveness across various applications, further solidifying its reputation in the industry.
Pricing and Availability
The Schneider LC1E1201E7 is competitively priced, offering excellent value for its features and performance. It is readily available through authorized distributors and online retailers, ensuring accessibility to customers worldwide.
Conclusion
In conclusion, the Schneider LC1E1201E7 stands out as a top choice for electrical contractors and professionals. Its comprehensive description encompasses its technical specifications, features, applications, and more. With its reliability, versatility, and user-friendly design, it continues to be a preferred solution for a wide range of electrical projects.
FAQs
- What is the warranty period for Schneider LC1E1201E7?
- The warranty period typically varies depending on the distributor and region. It is advisable to check with the supplier for specific warranty details.
- Can it be used in outdoor applications?
- While the Schneider LC1E1201E7 is designed for indoor use, there are outdoor-rated enclosures available for applications requiring outdoor installation.
- Is professional installation necessary?
- While professional installation is recommended for optimal performance and safety, experienced individuals with electrical knowledge can install it following the provided instructions.
- How does it compare to similar models from other brands?
- Schneider LC1E1201E7 offers competitive features, reliability, and pricing compared to similar models from other brands. However, it’s always advisable to compare specifications and user reviews before making a decision.
Are there any safety precautions to consider?
- As with any electrical component, safety precautions should be followed during installation and operation. This includes ensuring proper wiring, using appropriate protective gear, and following relevant safety standards and regulations.
Additional information
brands | Schneider Electric |
---|---|
Range | EasyPact |
Product or component type | Contactor |
Device short name | LC1E |
contactor application | Motor control Resistive load |
[Ie] rated operational current | 25 A (at <55 °C) at <= 440 V AC AC-1 for power circuit 12 A (at <55 °C) at <= 440 V AC AC-3 for power circuit |
Inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C) 95 VA 60 Hz cos phi 0.75 (at 20 °C) |
Auxiliary contact composition | |
Associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 25 A gG at <= 690 V coordination type 1 for power circuit |
Tightening torque | Power circuit: 1.2 N.m Control circuit: 1.2 N.m |
Mechanical durability | 10000000 cycles |
Mounting support | Plate DIN rail |
Pole contact composition | 3 NO |
Minimum switching current | 5 mA for control circuit |
Non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact |
Insulation resistance | > 10 MOhm for control circuit |
Connections - terminals | Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end Control cir |
Poles description | 3P |
minimum switching voltage | 17 V for control circuit |
Utilisation category | AC-1 AC-3 |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
Control circuit type | AC at 50/60 Hz |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
Maximum operating rate | 1800 cyc/h 60 °C |
Motor power kW | 3 kW at 220…230 V AC 50/60 Hz 5.5 kW at 380…400 V 5.5 kW at 415 V 5.5 kW at 440 V 7.5 kW at 500 V 7.5 kW at 660…690 V |
Rated breaking capacity | 96 A at 440 V for power circuit conforming to IEC 60947 |
Average impedance | 2.5 mOhm – Ith 25 A 50 Hz for power circuit |
Power dissipation per pole | 0.36 W AC-3 1.6 W AC-1 |
Electrical durability | 1400000 cycles AC-3 300000 cycles AC-1 |
Heat dissipation | 2…3 W for control circuit |
Operating time | 12…22 ms on closing 4…19 ms on opening |
Net weight | 0.3 kg |
Product certifications | CE EAC |
Overvoltage category | III |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Reviews