No products in the cart.
Schneider LC1E3801M5 | Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,38A,220V AC coil,50Hz,1NC auxiliary contact
Roll over image to zoom in
2,010 EGP3,722 EGP (-46%)
Schneider LC1E3801M5 | Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,38A,220V AC coil,50Hz,1NC auxiliary contact
Introduction to Schneider LC1E3801M5
Schneider LC1E3801M5 is a high-performance, reliable contactor designed to meet the demands of industrial applications. It is part of the TeSys E range of contactors manufactured by Schneider Electric, a global leader in energy management and automation solutions.
Specifications of Schneider LC1E3801M5
The Schneider LC1E3801M5 contactor features:
- Rated operational current: 80A
- Coil voltage: 24V AC
- AC-1 utilization category
- 3 main poles
- Compact design for easy installation
- DIN rail mounting
Applications of Schneider LC1E3801M5
Schneider LC1E3801M5 is suitable for various applications, including:
- Motor control
- Lighting control
- Heating control
- HVAC systems
- Industrial machinery
Features of Schneider LC1E3801M5
Key features of Schneider LC1E3801M5 include:
- High operational reliability
- Long electrical life
- Silent operation
- Built-in surge protection
- Easy maintenance
Installation Guide for Schneider LC1E3801M5
Installing Schneider LC1E3801M5 is straightforward. Follow these steps:
- Ensure power supply is disconnected.
- Mount the contactor on a DIN rail.
- Connect control wires to the coil terminals.
- Connect load wires to the main poles.
- Verify connections are secure.
- Restore power supply and test operation.
Maintenance Tips for Schneider LC1E3801M5
To ensure optimal performance, follow these maintenance tips:
- Regularly inspect for signs of wear or damage.
- Clean contacts and terminals as needed.
- Tighten any loose connections.
- Keep the contactor free from dust and debris.
Troubleshooting Common Issues with Schneider LC1E3801M5
If you encounter issues with Schneider LC1E3801M5, consider these troubleshooting steps:
- Check power supply and connections.
- Verify coil voltage and continuity.
- Inspect for overheating or abnormal noise.
- Refer to the user manual for specific troubleshooting guidance.
Comparing Schneider LC1E3801M5 with Similar Products
Schneider LC1E3801M5 offers several advantages over similar products, including:
- Higher operational reliability
- Enhanced durability
- Advanced features for improved performance
Customer Reviews and Feedback on Schneider LC1E3801M5
Customers praise Schneider LC1E3801M5 for its reliability and ease of installation. Many users report seamless integration into their industrial systems, with few instances of maintenance or performance issues.
Pricing and Availability of Schneider LC1E3801M5
Schneider LC1E3801M5 is competitively priced and widely available through authorized distributors and retailers. Pricing may vary based on quantity and location.
Warranty Information for Schneider LC1E3801M5
Schneider LC1E3801M5 comes with a standard warranty against manufacturing defects. Additional warranty options may be available for purchase.
Conclusion
In conclusion, Schneider LC1E3801M5 is a versatile and dependable contactor suitable for a wide range of industrial applications. With its robust design, advanced features, and ease of installation, it stands out as a top choice for professionals seeking reliable motor control solutions.
FAQs
- Is Schneider LC1E3801M5 suitable for outdoor use?
- Yes, Schneider LC1E3801M5 is designed to withstand various environmental conditions, making it suitable for outdoor installations.
- Can Schneider LC1E3801M5 be used with both AC and DC systems?
- No, Schneider LC1E3801M5 is specifically designed for AC applications and should not be used with DC systems.
- What is the electrical life expectancy of Schneider LC1E3801M5?
- Schneider LC1E3801M5 has a long electrical life expectancy, typically rated for thousands of operating cycles under normal conditions.
- Does Schneider LC1E3801M5 require any special maintenance?
- Regular inspection and cleaning are recommended to ensure optimal performance, but no special maintenance is required.
Where can I purchase Schneider LC1E3801M5?
- Schneider LC1E3801M5 is available through authorized distributors and retailers. You can also purchase it online through various e-commerce platforms.
Additional information
brands | Schneider Electric |
---|---|
Range | EasyPact |
Product or component type | Contactor |
Device short name | LC1E |
contactor application | Resistive load Motor control |
[Ie] rated operational current | 50 A (at <55 °C) at <= 440 V AC AC-1 for power circuit 38 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
Auxiliary contact composition | |
Associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit |
Tightening torque | Control circuit: 1.2 N.m Power circuit: 2.1 N.m |
Height (H) | 84 mm |
Width (W) | 56 mm |
Depth (D) | 86 mm |
Pole contact composition | 3 NO |
Irms rated making capacity | 380 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
Rated breaking capacity | 304 A at 440 V for power circuit conforming to IEC 60947 |
Average impedance | 2.5 mOhm – Ith 50 A 50 Hz for power circuit |
Mechanical durability | 8000000 cycles |
Control circuit type | AC at 50 Hz |
Inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C) 95 VA 60 Hz cos phi 0.75 (at 20 °C) |
Heat dissipation | 2…3 W for control circuit |
Operating time | 12…22 ms on closing 4…19 ms on opening |
Minimum switching current | 5 mA for control circuit |
Insulation resistance | > 10 MOhm for control circuit |
Non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact |
Mounting support | Plate DIN rail |
Poles description | 3P |
Product certifications | EAC CE |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Standards | IEC 60947-1 IEC 60947-5-1 IEC 60947-4-1 |
IP degree of protection | IP2X conforming to IEC 60529 |
Protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db |
Mechanical robustness | Vibrations contactor open (1.5 Gn, 5…300 Hz) Vibrations contactor closed (3 Gn, 5…300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms) |
Height | 84 mm |
Width | 56 mm |
Depth | 86 mm |