Outline Table
Heading | Subheading |
---|---|
Introduction | – What is Schneider LRE359? <br> – Importance of Thermal Overload Relays |
Features | – EasyPact TVS <br> – Current Rating and Class |
Working Principle | – Class 10A Description |
Benefits | – Overload Protection <br> – Safety Features |
Applications | – Industrial Machinery <br> – Electrical Systems |
Installation | – Guidelines for Proper Installation |
Maintenance | – Tips for Maintenance |
Troubleshooting | – Common Issues and Solutions |
Conclusion | – Recap of Key Points |
Schneider LRE359: The Innovative Thermal Overload Relay
In the realm of electrical protection and control, Schneider LRE359 stands out as a cutting-edge thermal overload relay designed to ensure the seamless operation of electrical systems. This article delves into the features, working principle, benefits, applications, installation, maintenance, troubleshooting, and more related to Schneider LRE359 and its class 10A description.
Introduction
Schneider LRE359 is a thermal overload relay that plays a crucial role in safeguarding electrical circuits from overload conditions. Understanding its significance requires insight into its components and functionality.
Features
EasyPact TVS
One of the standout features of Schneider LRE359 is its compatibility with EasyPact TVS, enhancing its efficiency and reliability in diverse applications.
Current Rating and Class
With a current rating ranging from 48A to 65A and a class 10A description, this relay is tailored to handle varying electrical loads effectively.
Working Principle
The class 10A description signifies the relay’s response time to overload conditions, providing rapid protection to electrical systems and preventing damage.
Benefits
Overload Protection
Schneider LRE359 offers robust overload protection, ensuring equipment longevity and minimizing downtime due to electrical faults.
Safety Features
Its advanced safety features provide peace of mind to operators, reducing the risk of electrical hazards in industrial environments.
Applications
Schneider LRE359 finds application in a wide range of scenarios, from industrial machinery to intricate electrical systems, offering reliable protection and control.
Installation
Proper installation is paramount for optimal performance. Following manufacturer guidelines and industry standards ensures the relay operates seamlessly within the electrical setup.
Maintenance
Regular maintenance is key to preserving the relay’s functionality. Routine checks and servicing contribute to extended equipment lifespan and enhanced performance.
Troubleshooting
Understanding common issues and their solutions empowers users to address potential problems swiftly, minimizing disruptions and ensuring continuous operation.
Conclusion
Schneider LRE359, with its advanced features, efficient working principle, and versatile applications, stands as a testament to Schneider Electric’s commitment to quality and innovation in electrical protection solutions.
FAQs
- What is the significance of the class 10A description in Schneider LRE359? The class 10A description indicates the relay’s quick response to overload conditions, enhancing system protection.
- Can Schneider LRE359 be used in residential settings? While primarily designed for industrial use, it can be adapted for specific residential applications with professional guidance.
- How often should Schneider LRE359 be inspected for maintenance purposes? Regular inspections, ideally as per manufacturer recommendations, ensure optimal performance and safety.
- Are there additional accessories available for Schneider LRE359? Yes, Schneider Electric offers a range of accessories to complement and enhance the functionality of LRE359.
- Does Schneider LRE359 integrate with digital monitoring systems? Yes, it can seamlessly integrate with digital monitoring systems, providing real-time data and enhancing overall system visibility and control.
Additional information
brands | Schneider Electric |
---|---|
Range | EasyPact |
Product or component type | Differential thermal overload relay |
Device short name | LRE |
Product name | EasyPact TVS |
Relay application | Motor protection |
Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
Auxiliary contact composition | |
Associated fuse rating | 100 A gG for power circuit 63 A aM for power circuit 5 A gG for signalling circuit |
phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1 |
Temperature compensation | |
Tightening torque | Power circuit: 9 N.m – on screw clamp terminals Signalling circuit: 1.7 N.m – on screw clamp terminals |
Connections - terminals | Signalling circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable |
Network type | AC |
Product compatibility | LC1E65…95 |
Thermal overload class | Class 10A conforming to IEC 60947-4-1 |
Signalling function | Relay trip indicator |
Local signalling | Trip indicator |
Control type | Push-button red stop: Push-button green reset: |
Net weight | 0.46 kg |
Dielectric strength | 6 kV at 50 Hz conforming to IEC 60255-5 |
Product certifications | EAC |
Fire resistance | 850 °C conforming to IEC 60068-2-1 |
Electromagnetic compatibility | |
Height | 54 mm |
Width | 70 mm |
Depth | 113 mm |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 8 cm |
Package 1 Width | 8.8 cm |
Package 1 Length | 12.7 cm |
Package 1 Weight | 479 g |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 9 |
Reviews